vehicle exhaust analyser Specification

  • Sensor Type
  • Electrochemical, NDIR
  • Orientation
  • Horizontal
  • Measurement
  • CO, HC measurement
  • Temperature
  • Operating: 0C to 50C
  • Display Type
  • Digital LCD
  • Efficiency
  • High Accuracy Measurement
  • Instruments Type
  • Gas Analyser
  • Power Source
  • Electric
  • Automation Grade
  • Automatic
  • Usage & Applications
  • Automobile emission testing, Pollution monitoring
  • Product Type
  • Vehicle Exhaust Analyser
  • Material
  • Mild Steel / ABS Plastic
  • Cooling System
  • Built-in Fan
  • Noise Level
  • <55 dB
  • Processing Time
  • Instantaneous
  • Voltage
  • 220V AC
  • Weight
  • Approx. 7 kg
  • Dimension (L*W*H)
  • 300mm x 220mm x 170mm
  • Surface
  • Anti-Corrosive Coating
  • Power Consumption
  • <50W
  • Data Storage
  • Internal memory for 2000 test results
  • Sample Inlet
  • Flexible Hose
  • Alarm System
  • Audio/Visual alarms for limit exceed
  • Calibration
  • Auto/Manual calibration option
  • Response Time
  • <30 seconds
  • Warm-up Time
  • <10 mins
  • Operating Humidity
  • 0-90% non-condensing
  • Interface
  • RS232 serial port for data transfer
  • Portable
  • Yes
 

vehicle exhaust analyser Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 30 Pieces Per Month
  • Delivery Time
  • 15 Days
 

About vehicle exhaust analyser



This Limited Time offer brings you a highly recommended, first-string Vehicle Exhaust Analyser designed for superior performance in automobile emission testing and pollution monitoring environments. In demand across India by manufacturers, suppliers, and traders, this prodigious solution features a robust RS232 interface, fast warm-up (<10 mins), and instantaneous processing. Enjoy auto/manual calibration, prodigious data storage (2000 tests), and audio/visual alarms for exceeding limits. Its compact, anti-corrosive mild steel/ABS body is portable and efficient, with high-accuracy measurement, built-in fan cooling, and a digital LCD display. Power-efficient, automated, and easy to operate-perfect for rigorous use.

Premium Build & Boundless Versatility

Crafted from anti-corrosive mild steel and ABS plastic, this analyser is engineered for durability and reliability. Equipped with a flexible hose sample inlet, it is ideal for precise automobile emission testing and pollution monitoring applications. The portable design, internal data storage for 2000 test results, and real-time audio/visual alarms highlight its advanced capabilities. Its automatic operation and high-accuracy sensors ensure superior performance regardless of usage scenario or operator experience.


Certifications, Delivery & Sample Policy Details

Each analyser is offered with trusted certifications to guarantee compliance and quality. Interested buyers can request a sample, with our sample policy tailored for your convenience. Expect a streamlined process from order to drop-off, with prompt arrival and expedited delivery times. We offer comprehensive post-sale support, ensuring safe transport and quick installation, so your business can benefit immediately from this cutting-edge pollution monitoring technology.


FAQ's of vehicle exhaust analyser:


Q: How does the vehicle exhaust analyser ensure measurement accuracy?

A: The analyser utilizes high-precision electrochemical and NDIR sensor technology, combined with auto/manual calibration, to provide highly accurate measurements for CO and HC levels in vehicle exhaust.

Q: What storage capabilities does the analyser offer for test results?

A: It features internal memory capable of storing up to 2,000 test results, allowing for sustained tracking and data analysis without immediate data transfer needs.

Q: Where is the analyser typically used?

A: This device is widely used in automobile emission testing centers, pollution control facilities, and automotive service stations across India for monitoring and regulatory compliance.

Q: What is the process for transferring data from the analyser?

A: You can easily transfer stored data via the RS232 serial port interface, supporting seamless integration with computers and central data systems.

Q: How does the built-in alarm system function?

A: The analyser's integrated audio and visual alarms activate when measured emissions surpass set safety limits, ensuring immediate attention and action by operators.

Q: When can I expect delivery after placing an order?

A: Delivery is typically prompt, with the product dispatched soon after order confirmation, ensuring quick drop-off and arrival at your location.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PUC Machines-Emission Testing Equipment Category

AIRVISOR GAS ANALYZER AVG500

AIRVISOR GAS ANALYZER AVG500

Minimum Order Quantity : 1 Piece

Efficiency : yes

Surface : metal

Display Type : LCD

Measurement : CO ,HC, O2, CO2

Temperature : 65 Celsius (oC)

PUC testing equipment

PUC testing equipment

Minimum Order Quantity : 1 Piece

Efficiency : High, >95%

Surface : Matte, AntiCorrosive

Display Type : Digital

Measurement : CO, HC, O2, NOx levels

Temperature : 0C to 50C Operating Range

pollution check device

pollution check device

Minimum Order Quantity : 1 Piece

Efficiency : High Fast Response

Surface : Matte Finish

Display Type : Digital Display

Measurement : Pollution/Emission Levels

Temperature : Ambient Operating Temperature

exhaust emission analyser

exhaust emission analyser

Minimum Order Quantity : 1 Piece

Efficiency : High Accuracy

Surface : Powder Coated / Painted Finish

Display Type : Digital LCD

Measurement : CO, CO2, HC, O2

Temperature : Operating 0C to 50C



Back to top